AIR-BLEED VALVES

ACCESSORIES
  • Maximum pressure: 400 bar
  • Available with GAS or METRIC thread

Hydraulic systems can effectively be bled with ABV air-bleed valves.
Easily installed, maintenance-free, almost unlimited service life, simple, safe, reliable and ef cient. The system can be operated immediately. No control irregularities due to air contamination of the pressure medium.

Cost saving: as non-productive de-aeration time is saved.

Air bleed between: opening pressure 0.1 bar and closing pressure about 1 bar.

AVB air-bleed valves are available with GAS or METRIC thread only for mineral oil based uids, and within the temperature limits of -15 °C to +90°C.

PRINCIPIO DI FUNZIONAMENTO

Il principio di funzionamento della valvola di sfiato si basa sulla differenza di comportamento di gas e liquidi sotto pressione, a seconda del loro grado di viscosità. un pistone, alloggiato nell’alesaggio del corpo con un determinato gioco, effettua l‘apertura e la chiusura della valvola all’avvio o all‘arresto del sistema.
Alla messa in funzione dell’impianto, l‘aria accumulata fuoriesce fino a che la colonna del liquido del fluido sotto pressione non raggiunge il pistone.
La pressione del liquido solleva il pistone contro la guarnizione superiore per alte pressioni, chiudendo in tal modo lo sfiato d’aria (è possibile che si verifichi una leggera fuoriuscita d’olio).
Quando la pressione diminuisce, la molla rilascia il pistone consentendo la riapertura dello sfiato d’aria, dopodichè la procedura può essere ripetuta. la speciale struttura del pistone evita l‘aspirazione dell’aria in caso di vuoto parziale.
La valvola di sfiato deve essere sistemata in posizione verticale, nel punto più alto del sistema idraulico o in posizioni in cui possono verificarsi accumuli d‘aria.
TOP